Find Nasopharyngeal Collection Nylon Flocked, Swab Test Kit, VTM UTM Swab Kit on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Medical Swab > VTM UTM Nasopharyngeal nylon flocked medical swab kit

VTM UTM Nasopharyngeal nylon flocked medical swab kit

  • VTM UTM Nasopharyngeal nylon flocked medical swab kit
  • VTM UTM Nasopharyngeal nylon flocked medical swab kit
  • VTM UTM Nasopharyngeal nylon flocked medical swab kit
  • VTM UTM Nasopharyngeal nylon flocked medical swab kit

VTM UTM Nasopharyngeal nylon flocked medical swab kit

    Payment Type: L/C,T/T,Western Union
    Terms of Trade: FOB,CFR,CIF,EXW,FCA,CPT,CIP
    Min. Order: 1000 Piece/Pieces
    Delivery Time: 1-3 Days
    Packaging: pouch/box/carton
    Productivity: 100K/day
    Brand: Poweray
    Transportation: Ocean,Land,Air
    Place of Origin: PR CHINA
    Supply Ability: 100M/month
    Certificate: CE
    HS Code: 3926909090
    Port: Hongkong,Shenzhen,Guangzhou

Basic Info

Model No.: VTM tube

Product Description


Disposable Sterilized vtm sampling swab virus transport medium


nasal thoroat swab with Universal Transport Medium is for collection, preservation, transport, chlamydia, mycoplasma and ureaplasma.


It provides a pH balanced environment and containsantibiotics to inhibit bacterial or fungal contamination.Microbeads inside the RNA ensure more rapid sample dispersion and elution


Packing specifications

Model: Non-Inactivated

Specification: 3mL/pc; 50pcs/box

Intended use

For the collection and delivery of clinical virus samples.

Principle

The solution in the inactivated sampling tube contains guanidine salts and other components, which can quickly cleave the virus to release nucleic acids and prevent nucleic acid degradation .

Swab To Vtm



[Main components]

---

Storage conditions and expiration date

Store at 2 30 ℃ in a dark place and dry place. Valid period is 12 months

Applicable Instruments

No special instrument is required for the operation of this sampling tube .

[Sample requirements]

1. Samples should be transported to the laboratory for testing immediately after collection ; if they cannot be delivered immediately , they should be stored at -70 ℃ or below and sent to the laboratory for testing within one week .

2. The sample should avoid repeated freezing and thawing .

Testing method

1. According to the sampling requirements, use a sampling swab to collect samples;

2. Place the sampling swab after collecting the sample into the sampling tube;

3. Break the swab at the easy break point of the sampling swab rod and discard the tail;

4. Tighten the sampling tube cover;

5. Mark the information on the sampling tube label as required .

Product Performance Index

1. Appearance

Inactivated: tube should be no damage and no leakage, the inner tube solution is orange or orange- red, clear liquid .

2. Loading

The volume of the tube should not be less than the indicated value.

3. pH value

Inactivated: when 25 ℃, pH value should be 6.5 ± 0. . 3 .

4. Difference between batches

Randomly draw three sampling tubes of different batch numbers to test the pH value, and the results should meet the requirements under the pH value item.

5 . Stability

To random sample within one month lifetime , were detected from 1 to 3, the result should comply with the requirements of 1 to 3 .

[Limitations of detection methods]

1. Samples must be collected following the clinically recommended sample collection guidelines .

2. Repeated freezing and thawing of samples may reduce the recovery rate of living organisms.

3. The virus sampling tube is only used for the collection and transportation of virus samples.

4. poly propylene or nylon flocked swab for specimen collection.

5. This product should be used in combination with rapid diagnostic kits or diagnostic instruments.

Precautions

1. This product is only used for in vitro diagnostics, for use by qualified personnel properly trained , before use should carefully read the instructions and follow carefully .

2. Each serving is for one person, for one-time use. Do not use it on more than one patient. Repeated use may lead to infection and/or inaccurate risks.

3. The sample may have microbiological risks, so when handling all items, the standard protection requirements of the medical institution should be followed.

4. After use, sterilize all biohazardous wastes (including samples, containers and media, etc.).

5. Do not re-sterilize unused swabs, the swabs are obviously damaged, please do not use.

6. It is forbidden to directly contact the sampling liquid with the person being collected, and it is forbidden to soak the swab with the sampling liquid before sampling .

7. Products that have expired or the product packaging is damaged shall not be used.

8. When the samples are tested, they should be operated in a laboratory that meets the safety level.

References

1. National Influenza Surveillance Technical Guide (2017 edition) .

2. Influenza A H1N1 Influenza Surveillance Plan (Second Edition) .

3. WHO global influenza network surveillance program .

ZSL MED

 

Zhenjiang SL Electronic Technology Co., Ltd. was founded in 2013, with a registered capital of 100 million yuan, is located in the beautiful historical and cultural city of Zhenjiang city, the company is headquartered in China small and Medium-sized enterprise information industry Park, a number of RESEARCH and development and production bases are located in Zhenjiang, Nanjing and other places.


Company is a leading Chinese Internet portable and medical equipment trade and a body comprehensive enterprise, main products and services cover portable medical equipment, special background and the APP, the database construction, database management and application, and with Tsinghua university, Shanghai yan chai hospital more than domestic top medical research institutions and units established a strategic cooperative partnership.


Company team members committed to accurate early cancer screening + intelligent slow disease supervision, independent research and development of ecg detecting system, screening system, such as the core technology, independent research and development the APP is used to collect a lot of slow heart monitoring, tumor detection map data and regional people health, the future through data technology solutions for mass slow disease, improve the health level.


Since its establishment, the company has persisted in making breakthroughs and developing in innovation, and applied for dozens of patents. It has been successively awarded the honorary titles of Jiangsu High-tech Enterprise, Jiangsu Private Science and Technology Enterprise, Innovation and Entrepreneurship Advanced Unit and so on. The products are widely used in hospitals at all levels, physical examination, public welfare for the aged and grass-roots medical institutions.


In the future, the company will continue to take early health screening as its development strategic goal, and strive to become a leading large technology complex industrial group in the health screening industry, so as to provide and create more high-quality products and services for customers and lead a more harmonious and healthy society.

Company Info

  • Company Name: ZSL MED
  • Representative: CHEN ZUBIN
  • Product/Service: Immunology Analyzer , Chemistry Analyzer , Hematology Analyzer , Urine Analyzer , SARS COV-2 POCT Analyzer , HbA1c Analyzer
  • Capital (Million US $): 100 Million RMB
  • Year Established: 2013
  • Total Annual Sales Volume (Million US $): US$1 Million - US$2.5 Million
  • Export Percentage: 31% - 40%
  • Total Annual Purchase Volume (Million US $): US$1 Million - US$2.5 Million
  • No. of Production Lines: above 20
  • No. of R&D Staff: 11 -20 People
  • No. of QC Staff: 5 -10 People
  • OEM Services Provided: yes
  • Factory Size (Sq.meters): 1,000-3,000 square meters
  • Factory Location: Building 3, 303, Yushan rd, Jingkou Dist. Zhenjiang city, Jiangsu,China
  • Contact Person: Mr. Richard
  • Tel: 86-755-23253102
Email to this supplier
  • *Subject:
  • To:

  • *Messages:
    Your message must be between 20-8000 characters